Immunoglobulin (IG) replacement products are used routinely in patients with immune deficiency and other immune dysregulation disorders who have poor responses to vaccination and require passive immunity conferred by commercial antibody products. The binding, neutralizing, and protective activity of intravenously administered IG against SARS-CoV-2 emerging variants remains unknown. Here, we tested 198 different IG products manufactured from December 2019 to August 2022. We show that prepandemic IG had no appreciable cross-reactivity or neutralizing activity against SARS-CoV-2. Anti-spike antibody titers and neutralizing activity against SARS-CoV-2 WA1/2020 D614G increased gradually after the pandemic started and reached levels comparable to vaccinated healthy donors 18 months after the diagnosis of the first COVID-19 case in the United States in January 2020. The average time between production to infusion of IG products was 8 months, which resulted in poor neutralization of the variant strain circulating at the time of infusion. Despite limited neutralizing activity, IG prophylaxis with clinically relevant dosing protected susceptible K18-hACE2–transgenic mice against clinical disease, lung infection, and lung inflammation caused by the XBB.1.5 Omicron variant. Moreover, following IG prophylaxis, levels of XBB.1.5 infection in the lung were higher in FcγR-KO mice than in WT mice. Thus, IG replacement products with poor neutralizing activity against evolving SARS-CoV-2 variants likely confer protection to patients with immune deficiency disorders through Fc effector function mechanisms.
Ofer Zimmerman, Alexa Michelle Altman Doss, Baoling Ying, Chieh-Yu Liang, Samantha R. Mackin, Hannah G. Davis-Adams, Lucas J. Adams, Laura A. VanBlargan, Rita E. Chen, Suzanne M. Scheaffer, Pritesh Desai, Saravanan Raju, Tarisa L. Mantia, Caitlin C. O’Shaughnessy, Jennifer Marie Monroy, H. James Wedner, Christopher J. Rigell, Andrew L. Kau, Tiffany Biason Dy, Zhen Ren, Jackson S. Turner, Jane A. O’Halloran, Rachel M. Presti, Peggy L. Kendall, Daved H. Fremont, Ali H. Ellebedy, Michael S. Diamond
Usage data is cumulative from January 2024 through June 2024.
Usage | JCI | PMC |
---|---|---|
Text version | 1,432 | 45 |
289 | 16 | |
Figure | 123 | 4 |
Supplemental data | 68 | 0 |
Citation downloads | 43 | 0 |
Totals | 1,955 | 65 |
Total Views | 2,020 |
Usage information is collected from two different sources: this site (JCI) and Pubmed Central (PMC). JCI information (compiled daily) shows human readership based on methods we employ to screen out robotic usage. PMC information (aggregated monthly) is also similarly screened of robotic usage.
Various methods are used to distinguish robotic usage. For example, Google automatically scans articles to add to its search index and identifies itself as robotic; other services might not clearly identify themselves as robotic, or they are new or unknown as robotic. Because this activity can be misinterpreted as human readership, data may be re-processed periodically to reflect an improved understanding of robotic activity. Because of these factors, readers should consider usage information illustrative but subject to change.